The Strong and Durable Server Rack Enclosures

If you are searching for a server rack solution that does not require you to leave your most valuable equipment just out in the open space. The server enclosures are the best solution! These electronics enclosure will surely remind you of your own cabinet or even wardrobe. These enclosed server racks are primarily designed to make your equipment safer and in contained comparison to an open rack.

These server racks can generally accommodate tons of weight and these can be locked on all of its sides in order to give the users the best protection. In addition to this, there are companies that can give you the best design to give you the best customized enclosed rack to be able to meet your companies’ needs.

These server rack electronics enclosures have different range of sizes. These can vary from 22U to 48U. In addition to this, the depth ranges of the electronics enclosure can vary from 20 inches to 48 inches in depth. If it is really needed, there are a lot of data cabinets that has an extended width for it to be able to accommodate cable-heavy engineer applications. The data center for some of the electronics enclosure has an unparalleled weight capacity. Some of the said cabinets can accommodate weights of up to 2,300 pounds.

Our data rack enclosures are available in either economically priced stocked configurations, for when you need the usual features, or custom-designed configurations for when you have special requirements in terms of size, function or features, color, or really anything else.

If you will be able to find the most suitable electronics enclosure server rack for your company that would be great! You just have to select and choose from wide range of products several companies have to offer. These companies can also give you server racks with just the normal features.

These companies can easily customize server rack enclosures for you to be able to meet your needs. Just give your preferred company the exact measurement you want to have for your server rack electronics enclosure as well as the needed functions and designs that can cater to your needs.

post

What is the Main Difference Between Server Cabinet and a Network Cabinet?

The server cabinet, which is also commonly called as an enclosed server rack, has a removable rear and front doors. The side panels and the adjustable vertical mounting rails are also included. The rack server cabinet that is being used in standard data center has a height of of 42U or 73.5 inches high. For the majority of server racks, these cabinets consist of 24 inches in width and they are 36 inches deep. Recently, the server cabinets have been popular across companies that has data centers and also server rooms.

A network cabinet is generally being used for several routers, switches, fiber patch panels as well as equipment being used for networking. For the majority of cases, the network cabinet is shallower compared to its server cabinet. They are generally less than 31 inches when it comes to deep measurement. There are times that it consists of a glass or it has a strong plastic front door. There is more to this also. The network cabinet commonly does not have perforated enclosures.

These type of cabinets are more popular because of the following primary reasons:

  1. Added security – compared to the insecure rack, the server rack cabinet gives added protection. The cabinets can be easily locked to avoid other visitors or unauthorized people to gain access to the equipment.
  2. Protection for Cables – together with the door and other side panels, the cables inside the server rack cabinet has much more less access compared to the outside air. This now helps in preservation of the cables in order to decrease the risk of cable damage because of some contaminants.
  3. Better filtration of air – the server cabinets can also be utilized by engineers to be able to provide a wide variety of air segregation or filtration strategies. For example, this can be used when there is a cold or hot aisle containment and cabinet-level type of containment.

With this in mind, there also comes some great disadvantages:

  1. High Price – unlike to the server rack, this cabinet is greatly more expensive.
  2. Cannot be accessed easily – because of some physical restrictions for this cabinet, it usually takes more time to do a manual operation or even do system maintenance of the equipment being housed inside the cabinet.

When a design engineer is building a data center, in deciding what type of server rack or cabinet to be used – and even network rack & cabinet – to use should be the top priority. The right one should be able to meet some of the installation demands and it can help you to greatly improve the power protection needed, including the cooling, cable management, and also the physical security.

post

What is the Best Rack Design that can Work Best for Your Engineering Project?

The majority of the server rack enclosure manufacturers will allow you to be able to select across several options, so that the server rack for your engineering project can meet the specific requirements where it will be installed (depending on the environment.) There are common areas where the engineer should be able to select options from.

  1. Shelving: the majority of the manufacturers can offer numerous options for your server rack shelves. This include some of adjustable or fixed server shelves that comes with four-point mounting. It also includes some keyboard shelves that has 2-point mounting. It is slightly vented, very durable, and has cantilever shelves. They also have media shelves. The project engineer should be able to effectively choose a server rack wit the depth of 6 inches that is lesser than the overall depth of the server rack. Once you have a server rack that is 30-inch deep cabinet, you should be able to effectively choose a shelf with a depth of 24 inches.
  2. Top and Side Panels: these panels are designed to give equipment protection from the foreign materials. The feature options that are included are the perforated slots for added ventilation, grommet holes designed to accommodate the supplementary cable management pathways, and there is also an option to mount the exhaust fans. The existing side panels gives security and they are most often available in wide variety of choices: solid fixed, solid removable, and solid that has vents included.
  3. Mounting rails: these are the most commonly used racks that comes with two different sets of mounting rails. In addition to this, the additional rail sets can be bought in order for it to accommodate the different depths in order to start rack loading. The majority of the manufacturers will allow the usage of these from either Universal Mounting Rails or EIA standard rails.
  4. Universal rails: they will be able to support the 19” EIA width rackmount including the networking equipment, and almost all of the server equipment. The EIA standard mounting rails will be able to support the 19” EIA width rackmount and also the additional networking equipment to be able to support the other manufacturers’ rack mounting equipment.

In addition to tis, whether the rails consist of square or tapped holes, the majority of the mounting rails should be able to comply with the ANSI/EIA-310-D standard (1992). The majority of the manufacturers of server rack recommends to purchase racks with rails that has square holes and cage nuts. Today, most of the off-the-shelf rack models are being used for rails that has square holes.

post

Managing Harsh Elements from Extreme Environments by Utilizing the Proper NEMA Cabinet

If you ever think that you are the toughest man, well think again! If you utilize server racks, they might be even tougher. However, not in the best way. A harshful environment can potentially bring severe damage in your server racks and other technological equipment if they are not being protected efficiently and properly. Extreme environments could potentially include some areas that has falling dirt, outdoor areas, dusty areas, as well as unfinished construction of warehouses.

In able to properly withstand these unideal environemtns to give efficient protection for your equipment, you probably need a NEMA rated server rack cabinet. These NEMA cabinets are initially designed to prvent dust, airborne particles, as well as dirt and other possible contaminants from totally damaging your valuable equipment. With this in mind, consider utilization of the following NEMA rated enclosures for harsh environments for each.

NEMA 12 Electronics Enclosure for Protection from Dust and Airborne Contaminants

These enclosure cabinets are originally made from steel and they are the most commonly used enclosure in environments like production facilities, factory floors, manufacturing fields, unfinished construction of warehouses, and many more. You can use NEMA 12 electronics enclosure in places where there are more dust particles floating around the air more than usual. These server cabinets have a gasketing system on all of its sides and doors and it leaves no room for contaminants to get inside of the enclosure. The normal cabinets also have existing vent patterns around the doors and its sides. While the NEMA 12 enclosures does not have these.

NEMA 3R Electronics Enclosure for Protection from Harmful Elements found in Outdoor Environments

These electronics enclosure can be utilized in both indoors and outdoors, but they are most commonly used for outdoor applications. The NEMA 3R cabinets can give protection for your equipment from solid object ingress brought by dust, dirt, and other particles floating in the air. NEMA 3R is similar to NEMA 12 in most of ways but NEMA 3R was also designed to give protection from other harmful environmental elements such as rain, ice, snow, and sleet.

These enclosure cabinets are primarily built using aluminum and they are mostly used for telecome applications. These applications involve the utilization of Wi-Fi, wireless/broadhband sites, fiber optics, and some trailer applications. The installati of fans or aircondiitoning units are beneficial for this type of enclosure. Especially if your equipment creates a certain amount of heat. The heaters are also widely available when the cabinet is going to be utilized in a very cold environment. The cold temperature can exceed the cold threshold which in return will be very damaging to the equipment as equivalent to too much heat exposure. The NEMA 3R enclosure can be wall mounted, pole-mounted or even pad-mounted (or freestanding.)

NEMA 4 or 4X for Protection from Possible Corrosion Formation or Hose Directed Water

The NEMA 4 and 4X are very in a large variety of ways. Both of these enclosures effectively address the major concerns of a NEMA 12 enclosure as well as the 3R enclosure. These enclosures can also give protection for your equipment against hose directed water. The NEMA 4X can also give you a specific protection from possible corrosion because it is entirely made from stainless steel. The NEMA 4 and 4X are going to be utilized for the same applications where the NEMA 3R is also used. NEMA 4 and 4X are very popular when they are used for traffic enclosures.

post

Managing Harsh Elements from Extreme Environments by Utilizing the Proper NEMA Cabinet

If you ever think that you are the toughest man, well think again! If you utilize server racks, they might be even tougher. However, not in the best way. A harshful environment can potentially bring severe damage in your server racks and other technological equipment if they are not being protected efficiently and properly. Extreme environments could potentially include some areas that has falling dirt, outdoor areas, dusty areas, as well as unfinished construction of warehouses.

In able to properly withstand these unideal environemtns to give efficient protection for your equipment, you probably need a NEMA rated server rack cabinet. These NEMA cabinets are initially designed to prvent dust, airborne particles, as well as dirt and other possible contaminants from totally damaging your valuable equipment. With this in mind, consider utilization of the following NEMA rated enclosures for harsh environments for each.

NEMA 12 Electronics Enclosure for Protection from Dust and Airborne Contaminants

These enclosure cabinets are originally made from steel and they are the most commonly used enclosure in environments like production facilities, factory floors, manufacturing fields, unfinished construction of warehouses, and many more. You can use NEMA 12 electronics enclosure in places where there are more dust particles floating around the air more than usual. These server cabinets have a gasketing system on all of its sides and doors and it leaves no room for contaminants to get inside of the enclosure. The normal cabinets also have existing vent patterns around the doors and its sides. While the NEMA 12 enclosures does not have these.

NEMA 3R Electronics Enclosure for Protection from Harmful Elements found in Outdoor Environments

These electronics enclosure can be utilized in both indoors and outdoors, but they are most commonly used for outdoor applications. The NEMA 3R cabinets can give protection for your equipment from solid object ingress brought by dust, dirt, and other particles floating in the air. NEMA 3R is similar to NEMA 12 in most of ways but NEMA 3R was also designed to give protection from other harmful environmental elements such as rain, ice, snow, and sleet.

These enclosure cabinets are primarily built using aluminum and they are mostly used for telecome applications. These applications involve the utilization of Wi-Fi, wireless/broadhband sites, fiber optics, and some trailer applications. The installati of fans or aircondiitoning units are beneficial for this type of enclosure. Especially if your equipment creates a certain amount of heat. The heaters are also widely available when the cabinet is going to be utilized in a very cold environment. The cold temperature can exceed the cold threshold which in return will be very damaging to the equipment as equivalent to too much heat exposure. The NEMA 3R enclosure can be wall mounted, pole-mounted or even pad-mounted (or freestanding.)

NEMA 4 or 4X for Protection from Possible Corrosion Formation or Hose Directed Water

The NEMA 4 and 4X are very in a large variety of ways. Both of these enclosures effectively address the major concerns of a NEMA 12 enclosure as well as the 3R enclosure. These enclosures can also give protection for your equipment against hose directed water. The NEMA 4X can also give you a specific protection from possible corrosion because it is entirely made from stainless steel. The NEMA 4 and 4X are going to be utilized for the same applications where the NEMA 3R is also used. NEMA 4 and 4X are very popular when they are used for traffic enclosures.

post

How to Reduce the Sound Produced in Your Data Space through Sound Proof Server Cabinet?

Most of the time, students have been continually complaining about the loud sound the equipment in their school produces while they were taking tests or having a class lecture. There is one best solution to this problem: sound proof cabinets. Not only it can address the loud sound in schools, but it can also serve the loud sound in other environments. It can reduce the noise up to 26 dBa, which is most likely to reducing a loud noise to a whisper.

The electronics enclosure was proven to create a very huge difference to those that has been very affected by very loud environment. Together with several different size options that is widely available (9u to 44u). There are also several different styles for the cabinets such as wall mounts as well as standing server cabinets. But companies can be assured that there is an existing sound proof cabinet for every application.

Sound reduction is not the only priority. A common concern when considering enclosed server rack cabinets like the Sound Proof is heat. In an enclosed space it can be very easy for equipment to become overheated, which can lead to all sorts of detrimental equipment failures. But, Sound Proofs have it covered.

In addition to the decreasing of disturbing sound, the sound cabinets can also release up to 12kW worth of heat. What is the most interesting characteristic about these cabinets is that the topmost part of the wardrobe allows the cooler air to come in through the wardrobe doors. With this in mind, the hot air is now being pushed out from the topmost part of the rear wardrobe doors installed on the cabinet. The doors makes allowance for the cool air to properly circulate in the rack area and this system can make the cabinet at good acceptable temperature.

Sound Proof Cabinets may sound to good to be true, but the features that the sound proof cabinets have been offering are very safe and very secure. The manufacturers of these cabinets clearly knows that keeping the equipment is very important as well as protecting your equipment is vitally crucial.

This is the very reason why companies have the option to be able to effectively upgrade your server cabinets that comes together with wide options of security options – from having security cameras to having electronic locking systems. When it finally comes to proper cable management, we don’t have to worry about having the cables confusingly intertwined to each other.

The sound proof cabinets were designed to have 6 cable points of entry on each side: 3 on topmost and 3 on the bottom part. This design should not compromise the sound of reduction being produced. The data center cabinets also came with rack casters accessories to make the cabinets more mobile in case companies wants them to move around.

post

5 Effective Tips to Achieve Data Center’s Efficiency in Electricity

Along with airflow and cooling, using the right tools to monitor your power usage can also be very effective. The following are 10 improvements you can make in your data center in order to improve your energy efficiencies and ultimately save money.

1) Contain your aisles with doors and rack top baffles

As mentioned earlier, aisle containment helps to keep hot air in one section of the data center and cold air in another. This allows for a more natural flow of air in your space, which naturally creates lower energy usage. Upsite’s AisleLok Aisle Containment systems are extremely easy to install and get the job done! You can learn more about this innovative technology from Upsite, here.

2) Utilize proper cable management to increase airflownp-2-sp

Believe it or not, the ways your cables are configured make a big difference in airflow. If your cables are all tangled, they could be blocking air from going in and out of your racks. We sell hundreds of cable management tools that can make your cables organized and improve your airflow all at the same time. You can also read more about some of our cable management tips here.

3) Decommission unused servers

You may have servers in your data center that are using energy but are not actually doing anything. In that case, decommission these devices. If they do not serve a purpose in your data center, then they do not need to be using valuable power resources.

4) Replace inefficient PDUs and Servers with energy star rated equivalents

Energy Star Rated equipment meets the guidelines of energy efficiency mandated by the federal government. PDUs and servers that are not Energy Star Rated could potentially be using too much energy in an inefficient way, which drives up your costs. Swap out old, inefficient equipment with updated, Energy Star Rated equipment.

5) Use high efficiency UPS Systemsenterpriseplus-rack-front-1

UPS systems help to protect your equipment from surges and spikes in power as well as prevent downtime. Even though using these devices means that you’ll have more equipment using power in your data center, UPS systems use power efficiently and give you insight into how your other equipment is using power. For more information on how to shop for a UPS, read our guide.